Dane Telemetryczne

Tabela Opisów Data Types

Aby lepiej zrozumieć typ pomiaru związany z udostępnionym dataType, można odwołać się do rysunku (który przedstawia schemat wysokiego poziomu kompletnej instalacji) i tabela poniżej (dostępna tylko w języku Angielskim).


Category

dataType Name

dataType Description


Power (W)

GenerationPower

Power generated by the inverter on the AC side. Includes battery discharge power contribution.


Power (W)

DCGenerationPower

Power generated by the inverter on the DC side. Does not include battery discharge power contribution.


Power (W)

GridPowerExport

Exported/Imported power, to/from the grid, detected by a meter. Negative value for import, positive value for export.


Power (W/m2 )

Irradiance

Irradiance detected by a sensor, standalone or integrated in a weather station, correctly installed.


Power (W)

StoredPower

Discharged/Charged power detected by a battery. Negative value for charge, positive value for discharge.


Frequency (Hz)

LineFrequency

Frequency measured by the inverter on the AC side.


Wind (°N)

WindDirection

Wind direction detected by a sensor, standalone or integrated in a weather station, correctly installed.


Wind (km/h)

WindSpeed

Wind speed detected by a sensor, standalone or integrated in a weather station, correctly installed.


Temperature (°C)

CellTemp

Cell temperature detected by a sensor, standalone or integrated in a weather station, correctly installed.


Temperature (°C)

AmbientTemp

Ambient temperature detected by a sensor, standalone or integrated in a weather station, correctly installed.


Voltage (V)

Voltage

Voltage measured by the inverter on the AC side.


Voltage (V)

DCVoltage

Frequency measured by the inverter on the DC side.


Current (A)

Current

Current measured by the inverter on the AC side.


Current (A)

DCCurrent

Current measured by the inverter on the AC side.


Energy (Wh)

GenerationEnergy

Energy generated by the inverter on the AC side. Includes battery discharge energy contribution.


Energy (Wh)

DCGenerationEnergy

Energy generated by the inverter on the DC side. Does not include battery discharge energy contribution.


Energy (Wh/m2)

Insolation

Insolation detected by a sensor, standalone or integrated in a weather station, correctly installed.


Energy (Wh)

StorageInEnergy

Charged energy detected by a battery.


Energy (Wh)

StorageOutEnergy

Discharged energy detected by a battery.


Energy (Wh)

GridEnergyExport

Exported energy, to the grid, detected by a meter.


Energy (Wh)

GridEnergyImport

Imported energy, to the grid, detected by a meter.


Energy (Wh)

SelfConsumedEnergy

Self-Consumption of home loads, coming from renewable sources only.


Power-Based KPI (%)

StateofCharge

State of charge detected for a battery.


Power-Based KPI (%)

StateofHealth

State of health detected for a battery.


Power-Based KPI (W)

LoadsPowerConsumed

Consumption of home loads, coming from renewable sources and the grid.


Energy-Based KPI (%)

SelfConsumption

Percentage of Self-Comsumption (how much energy, coming only from renewable sources, has been exported to the grid compared to the self-consumed one) detected.


Energy-Based KPI (%)

SelfSufficiency

Percentage of Self-Sufficiency (how much energy has been imported from the grid compared to the self-consumed one) detected.


Energy-Based KPI (%)

PerformanceRatio

Percentage of performance detected based on the algorithm set.


Energy-Based KPI (Wh)

LoadsEnergyConsumed

Consumption of home loads, coming from renewable sources and the grid.


Power (W)

ActivePowerEV

Power generated by the AC wallbox. Different from zero only during a charging session.


Energy (Wh)

SessionEnergyEV

Total energy flowed from the AC wallbox during a charging session.


Energy (Wh)

ActiveEnergyEV

Total energy flowed from the AC wallbox over the lifetime.