Données de Télémétrie
Tableau de description des Data Types
Pour mieux comprendre le type de mesure associé au dataType
mis à disposition, il est possible de se référer à la figure (qui propose un schéma de haut niveau d’une installation complète) et tableau ci-dessous (uniquement disponible en Anglais).
Category
dataType Name
dataType Description
Power (W)
GenerationPower
Power generated by the inverter on the AC side. Includes battery discharge power contribution.
Power (W)
DCGenerationPower
Power generated by the inverter on the DC side. Does not include battery discharge power contribution.
Power (W)
GridPowerExport
Exported/Imported power, to/from the grid, detected by a meter. Negative value for import, positive value for export.
Power (W/m2 )
Irradiance
Irradiance detected by a sensor, standalone or integrated in a weather station, correctly installed.
Power (W)
StoredPower
Discharged/Charged power detected by a battery. Negative value for charge, positive value for discharge.
Frequency (Hz)
LineFrequency
Frequency measured by the inverter on the AC side.
Wind (°N)
WindDirection
Wind direction detected by a sensor, standalone or integrated in a weather station, correctly installed.
Wind (km/h)
WindSpeed
Wind speed detected by a sensor, standalone or integrated in a weather station, correctly installed.
Temperature (°C)
CellTemp
Cell temperature detected by a sensor, standalone or integrated in a weather station, correctly installed.
Temperature (°C)
AmbientTemp
Ambient temperature detected by a sensor, standalone or integrated in a weather station, correctly installed.
Voltage (V)
Voltage
Voltage measured by the inverter on the AC side.
Voltage (V)
DCVoltage
Frequency measured by the inverter on the DC side.
Current (A)
Current
Current measured by the inverter on the AC side.
Current (A)
DCCurrent
Current measured by the inverter on the AC side.
Energy (Wh)
GenerationEnergy
Energy generated by the inverter on the AC side. Includes battery discharge energy contribution.
Energy (Wh)
DCGenerationEnergy
Energy generated by the inverter on the DC side. Does not include battery discharge energy contribution.
Energy (Wh/m2)
Insolation
Insolation detected by a sensor, standalone or integrated in a weather station, correctly installed.
Energy (Wh)
StorageInEnergy
Charged energy detected by a battery.
Energy (Wh)
StorageOutEnergy
Discharged energy detected by a battery.
Energy (Wh)
GridEnergyExport
Exported energy, to the grid, detected by a meter.
Energy (Wh)
GridEnergyImport
Imported energy, to the grid, detected by a meter.
Energy (Wh)
SelfConsumedEnergy
Self-Consumption of home loads, coming from renewable sources only.
Power-Based KPI (%)
StateofCharge
State of charge detected for a battery.
Power-Based KPI (%)
StateofHealth
State of health detected for a battery.
Power-Based KPI (W)
LoadsPowerConsumed
Consumption of home loads, coming from renewable sources and the grid.
Energy-Based KPI (%)
SelfConsumption
Percentage of Self-Comsumption (how much energy, coming only from renewable sources, has been exported to the grid compared to the self-consumed one) detected.
Energy-Based KPI (%)
SelfSufficiency
Percentage of Self-Sufficiency (how much energy has been imported from the grid compared to the self-consumed one) detected.
Energy-Based KPI (%)
PerformanceRatio
Percentage of performance detected based on the algorithm set.
Energy-Based KPI (Wh)
LoadsEnergyConsumed
Consumption of home loads, coming from renewable sources and the grid.
Power (W)
ActivePowerEV
Power generated by the AC wallbox. Different from zero only during a charging session.
Energy (Wh)
SessionEnergyEV
Total energy flowed from the AC wallbox during a charging session.
Energy (Wh)
ActiveEnergyEV
Total energy flowed from the AC wallbox over the lifetime.